Shop Espresso at BUNN.com. BUNNserve Support Locations. Catalog: Home / Equipment & Accessories / Espresso. Coffee Espresso Bean to Cup Iced Tea Coffee & Tea Combos Cold Coffee Juice Frozen Granita/Slushy. Black & White BW3-CTMS Black & White 3 CTMS Automatic Espresso Machine with Steam Wand D. View and Download Bunn Tiger Super Automatic Espresso Machine with Steam Wand XL S-2 specification sheet online. Tiger Super Automatic Espresso Machine with Steam Wand. Tiger Super Automatic Espresso Machine with Steam Wand XL S-2 Coffee Maker pdf manual download.
Thermal Carafe Coffee Brewer
- Free kitchen appliance user manuals, instructions, and product support information. Find owners guides and pdf support documentation for blenders, coffee makers, juicers and more.
- BUNN - Home Products & Accessories. Explore quality products made by the artisans at BUNN Gourmet® and sourced from other fine craftsmen.
- Free kitchen appliance user manuals, instructions, and product support information. Find owners guides and pdf support documentation for blenders, coffee makers, juicers and more. Bunn Coffeemaker A10 Automatic User Guide ManualsOnline.com.
Pourover and Automatic
Features
Model | Model |
CW15-TC | CWTF15-TC |
(no warmers) (thermal carafe sold separately)
Dimensions: 17.9” H x 9” W x 18.5” D
(45.5cm H x 22.9cm W x 55.4cm D)
Model CDBCF15-TC
12 Cup Pourover and Automatic Coffee Brewer, CW-TC & CWTF-TC
•Brews 3.9 to 6.8 gallons (14.78 to 25.77 liters) of perfect coffee per hour.
•Accepts thermal carafe up to 8.5” tall (21.6cm).
•Use in quick turn environment where high quality coffee is continuously refreshed.
•Models are space saving 9.0” wide (22.9cm).
•All stainless steel construction.
•Hot water faucet available on automatics
•SplashGard® funnel deflects hot liquids away from the hand.
•Pourover model requires no plumbing and is completely portable. Just pour cold water in top and coffee brews immediately.
12 Cup Automatic Coffee Brewer, CDBCF
•Automatically adjusts to varying water pressure.
•Quicker install with pot level, cold brew lock-out and tank temperature set using the simple-to-program touch pad controls.
•Faster service by use of feedback information from built-in electronic diagnostics.
Shown with Thermal Carafe
(no warmers) (thermal carafe sold separately)
Dimensions: 17.9” H x 9” W x 18.5” D
(45.5cm H x 22.9cm W x 55.4cm D)
For current specification sheets and other information, go to www.bunn.com. * International models may vary in appearance.
Related Products
Easy Clear® EQ-17-TL
Product No. : 30200.1000
Dimensions:
127⁄16' H x 21⁄2' W x 3' D
31.6 cm H x 6.35 cm W x 7.62 cm D
Thermal Carafe
Product No. : 18022.6002 Capacity 1.9 liter (64 oz) Dimensions: 8'H x 6.4'W x 8.2'D
(20.3cm H x 16.3cm W x 21cm D)
Paper Filter Pack
Bunn Dual Coffee Maker Manual
Product No. : 20115.6000 Packed per case: 1,000
Dimensions: 41⁄4' Base x 23⁄4' Sidewall 10.8 cm Base x 6.98 cm Sidewall
Model | Agency Listing | |
CWTF15-TC | CW15-TC | |
CDBCF15-TC | ||
E9001.7044B | Patents Apply | 09/06 A3.13 |
Dimensions & Specifications | CANADA | ||||||||
Model | Product # | Volts | Amps Tank Htr | Total | Capacity | Cubic | Weight | Cord | |
Watts | Watts | per hour | ft3/m3 | lbs/kg | Attached | ||||
CW15-TC | 23001.6057 | 120 | 12.1 | 1450 | 1450 | 3.9 gal/14.78 liter | 6.3/.178 | 28 / 12.7 | Yes** |
CW15-TC* | 23001.6058 | 120 | 12.1 | 1450 | 1450 | 3.9 gal/14.78 liter | 6.3/.178 | 28 / 12.7 | Yes** |
CWTF15-TC* | 12950.6104 | 120 | 12.1 | 1450 | 1450 | 3.9 gal/14.78 liter | 6.3/.178 | 35 / 15.9 | Yes** |
CWTF35-TC | 12950.6107 | 120/240 | 14.6 | 3500 | 3500 | 6.8 gal/25.77 liter | 5.1/.144 | 34 / 15.4 | No |
CDBCF15-TC* | 29000.6012 | 120 | 12.5 | 1450 | 1500 | 4.2 gal/15.92 liter | 5.1/.144 | 31 / 14.1 | Yes** |
CDBCF35-TC* | 29000.6015 | 120/240 | 14.6 | 3500 | 3500 | 6.8 gal/25.77 liter | 5.1/.144 | 29 / 13.2 | No |
* Includes a stainless steel funnel **Power cord (NEMA 5-15P) 15 Amp-120V machine only.
Brewing capacity: based upon incoming water temp of 60ºF (140ºF rise) per 1/2 gallon brew time of 4 minutes.
Models listed as 120/208V or 120/240V must be connected to 208V or 240V electrical service respectively. Please refer to the installation manual.
Electrical: Requires 2-wires plus ground service rated 120V single phase, 60 Hz. Plumbing: 20-90 psi (138-621 kPa).Machine supplied with1⁄4' male flare fitting.
CWTF15-TC
CDBCF15-TC
Bunn-O-Matic Corporation of Canada - 280 Industrial Pkwy. S. Aurora, Ontario L4G 3T9 • 905-841-2866 • Fax 905-841-2775 • www.bunn.com
BUNN® practices continuous product research and improvement.We reserve the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
All dimensions shown in inches. Bunn Corporation owns all copyrights relating to materials in this publication. Please contact Bunn Corporation to request permission to reproduce any portion of this publication.
A10 Automatic &
A10A Automatic
Supplement to A10 Use & Care
Booklet #10070.0000
INSTALLATION & OPERATION
INTRODUCTION
This equipment will automatically brew a 48 ounce batch of coffee into an awaiting decanter and has a pour-over feature for emergency use. It is only for indoor use on a sturdy counter or shelf.
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and appearing within one year from the date of installation. This warranty does not apply to any equipment, component or part that was not manufactured by Bunn or that, in Bunn’s judgement, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of Bunn are not authorized to make modifications to this warranty or to make additional warranties that are binding on Bunn. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.
The Buyer shall give Bunn prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois, 62708-3227. If requested by Bunn, the Buyer shall ship the defective equipment prepaid to an authorized Bunn service location. If Bunn determines, in its sole discretion, that the equipment does not conform to the warranty, Bunn shall repair the equipment with no charge for parts during the one year warranty period and no charge for labor by a Bunn Authorized Service Representative during the one year warranty period. If Bunn determines that repair is not feasible, Bunn shall, at its sole option, replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AS SPECIFIED HEREIN, TO REPAIR OR, AT BUNN’S SOLE OPTION, REPLACEMENT OR REFUND. Bunn shall not be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
TELEPHONE: (217) 529-6601 FAX: (217) 529-6644
USER NOTICES
The notices on this brewer should be kept in good condition. Replace unreadable or damaged labels.
! WARNING
Fill water tank before turning -on thermostat or connecting appliance to power source.
Use only on a properly protected circuit capable of the rated load. Electrically ground the chassis.
Follow national/local electrical codes.
Do not use near combustibles.
FAILURE TO COMPLY RISKS EQUIPMENT
DAMAGE, FIRE, OR SHOCK HAZARD
READ THE ENTIRE OPERATING MANUAL
BEFORE BUYING OR USING THIS PRODUCT
THIS APPLIANCE IS HEATED WHENEVER
CONNECTED TO A POWER SOURCE
00831.0000F 3/98 © 1988 BUNN-O-MATIC CORPORATION
#00831.0000
This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
#00656.0000
ELECTRICAL REQUIREMENTS
CAUTION - Do not plug-in the brewer until specified in Initial Set-Up.
The A10 Automatic Brewer has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 10 amp, single phase, 60 Hz.
The A10A Automatic Brewer has an IEC 320 connector and matching cordset and requires 2-wire grounded service rated 230 volts ac, 10 amp, single phase, 50-60 Hz. The appropriate cordset connector must be supplied when installing the brewer.
PLUMBING REQUIREMENTS
This brewer must be connected to a cold water system with operating pressure between 20 and 90 psi from a 1/2' or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi to reduce it to 50 psi. The water inlet fitting is 1/4' flare.
NOTE –Bunn-O-Matic recommends 1/4' copper tubing for installations of less than 25 feet and 3/8' for more than 25 feet from the 1/2' water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the brewer will facilitate movement to clean the countertop. It can be purchased direct from Bunn-O-Matic (part number 00326-0000).
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA)
and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
Plumbing Hook-Up
1.Attach the flare fitting from the short piece of tubing on the flow control (supplied) to the water inlet fitting on the left rear side of the brewer.
2.Flush the water line and securely attach it to the flare fitting on the strainer.
3.Turn on the water supply.
INITIAL SET-UP
CAUTION –The brewer must be unplugged throughout the initial set-up, except when specified in the instructions.
1.Insert an empty funnel into the funnel rails.
2.Place an empty decanter under the funnel.
3.Pour three pitchers of tap water into the screened area on top of the brewer. Allow approximately two minutes between pitchers for water to flow into the tank. While the third pitcher of water is entering the tank, the tank will fill to capacity and the excess will flow from the sprayhead, out of the funnel, and into the decanter.
4.When the flow of water from the funnel stops, plug-in the brewer and place the heater switch on the left side of the brewer in the “ON” lower position. Wait approximately twenty minutes for the water in the tank to heat to the proper temperature. Some water will drip from the funnel during this time; this is due to expansion and should not occur thereafter.
5.Empty the decanter, return it to the warmer, place the warmer switch in the “ON” (lighted) position, and momentarily press and release the start switch.
6.Place the warmer switch in the “OFF” (unlighted) position after water has stopped flowing from the funnel, and let the water in the tank reheat to the proper temperature.
7.Empty the decanter, place the warmer switch in the “ON” (lighted) position, and momentarily press and release the start switch. Check the water volume in the decanter after water has stopped flowing from the funnel. It should be 48 ounces.
INITIAL SET-UP (CONT.)
8.If not, locate the brew timer near the heater switch on the left side of the brewer, adjust the brew timer dial up-or-down as required and allow the water to reheat. Start, and measure another brew cycle.
9.Repeat step 8 until 48oz water volume is achieved.
10.The brewer is now ready for use in accordance with the coffee brewing instructions.
OPERATING CONTROLS
Warmer Switch
Placing the switch in the unlighted position cuts power to the brew station warmer and stops brewing. Stopping a brew cycle after it has been started will not stop the flow of water into the funnel until the tank syphons down to its proper level. Placing the switch in the lighted position supplies power to the brew station warmer and enables the brew circuit.
Start
Momentarily pressing and releasing this switch starts a brew cycle when the warmer switch is in the lighted position.
NOTE –The warmer switch must be in the lighted position to initiate and complete a brew cycle.
Full/Half
Placing this switch in the half position yields approximately 24 ounces.
COFFEE BREWING
1.Insert a BUNN® filter into the funnel.
Bunn Automatic Cappuccino Machine User Manual Pdf
2.Pour the fresh coffee into the filter and level the bed of grounds by gently shaking.
3.Slide the funnel into the funnel rails.
4.Place an empty decanter under the funnel.
5.Place the warmer switch in the lighted position. Momentarily press and release the start switch.
6.When brewing is completed, simply discard the grounds and filter.
CLEANING
1.The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment.
2.Check and clean the sprayhead. The sprayhead holes must always remain open.
3.With the sprayhead removed, insert the deliming spring (provided) all the way into the sprayhead tube. When inserted properly, no more than two inches of spring should be visible. Saw back and forth five or six times.
NOTE – In hard water areas, this may need to be done daily. It will help prevent liming problems in the brewer and takes less than a minute.
REPLACEMENT PARTS
04060.0000 ........... | BASE EXTRUSION | 04067.0001 ........... | SWITCH, LIGHTED ON/OFF 120V (A10) |
04040.0004 ........... | BREW FUNNEL, BLACK | 04039.0000 ........... | SWITCH, LIGHTED ON/OFF 240V (A10A) |
04069.0003 ........... | CONTROL THERMOSTAT ASSY. | 21274.0000 ........... | SWITCH, START |
01716.0000 ........... | CORD, POWER 250V 10 AMP, IEC320 (A10A) | 04786.0002 ........... | SWITCH, VACATION |
01637.0000 ........... | CORDSET, 16/3HSJO NEMA 5-15P (A10) | 05518.0000 ........... | SYPHON HUB |
04123.0001 ........... | COVER, TOP BLACK | 04174.0000 ........... | TANK HEATER 1000W 240V (A10A) |
00658.0000 ........... | DECAL, CAUTION DECANTER & FUNNEL | 00943.0000 ........... | TANK HEATER GASKET |
21139.0002 ........... | DECAL, FRONT END CAP | 00942.0002 ........... | TANK HEATER NUT |
00831.0000 ........... | DECAL, WARNING ELECTRICAL | 04144.0000 ........... | TANK HEATER, 1000W 120V (A10) |
01193.0000 ........... | DELIMING SPRING | 01932.0000 ........... | TANK KEEP WARM HEATER, 34W 240V (A10A) |
04124.0001 ........... | FLIP LID, BLACK | 04100.0000 ........... | TANK KEEP WARM HEATER, 40W 120V (A10) |
01148.0001 ........... | FLOW CONTROL & STRAINER ASSY, .222 GPM | 04142.0000 ........... | TANK LID |
20526.0222 ........... | FLOW WASHER, .222 GPM | 04844.0000 ........... | TANK LID GASKET |
04002.1000 ........... | FOOT | 00960.0001 ........... | TANK LID INLET FITTING |
21327.0001 ........... | FRONT END CAP, BLK | 01540.0000 ........... | TANK LID INLET FITTING WASHER |
04063.0000 ........... | HOOD EXTRUSION, LEFT | 01201.0000 ........... | TANK LID INLET GASKET |
04062.0000 ........... | HOOD EXTRUSION, RIGHT | 04167.0001 ........... | THERMAL CUT OFF W/RED LEADS (A10A) |
04041.0003 ........... | HOT WATER FUNNEL, BLACK | 21453.0000 ........... | TIMER BOARD SHIELD |
04097.0002 ........... | POUR-IN BASIN, BLACK AUTO | 02620.1042 ........... | TIMER, 120V 3-BATCH (A10) |
01908.0000 ........... | POWER CONNECTOR, IEC320 (A10A) | 02620.1043 ........... | TIMER, 240V 3 BATCH (A10A) |
04016.0001 ........... | REAR END CAP, BLK | 04065.0000 ........... | TRUNK EXTRUSION, LEFT |
01975.0000 ........... | SOLENOID VALVE 240V (A10A) | 04064.0000 ........... | TRUNK EXTRUSION, RIGHT |
01085.0000 ........... | SOLENOID VALVE, 120V (A10) | 04012.0007 ........... | TRUNK REAR, BLK (A10) |
01075.0000 ........... | SPRAYEHAD FITTING NUT | 04012.0008 ........... | TRUNK REAR, BLK (A10A) |
04011.0000 ........... | SPRAYHEAD PANEL | 21214.0000 ........... | TUBE ASSY, FILL BASIN |
04045.0000 ........... | SPRAYHEAD, 5 HOLE PLASTIC | 04095.0003 ........... | WARMER ASSY W/LEADS, BLK 80W 230V (A10A) |
01082.0004 ........... | SPRAYHEAD, 5 HOLE STAINLESS STEEL | 04095.0002 ........... | WARMER ASSY W/LEADS, BLK 80W 120V (A10) |
00707.0000 ........... | STRAIN RELIEF BUSHING (A10) | 04021.0002 ........... | WARMER FRAME, BLACK |
04052.0000 ........... | SWITCH BRACE | 04870.0000 ........... | WATER PITCHER, 48 OZ |
21273.0000 ........... | SWITCH, HALF BATCH |
SCHEMATIC WIRING DIAGRAM A10 AUTO
L1 | SW. & | GREEN | N | |
LIMIT | LIMIT | |||
SW1 | THERMOSTAT | |||
THERMOSTAT | THERMOSTAT | |||
BLK | BLU | BLK | 1000W | WHI |
WHI | 40W | TANK HEATER | WHI | |
SW2 | 'KEEP WARM' HEATER | WHI | ||
WHI | 80W | WHI | ||
BLK | BLK | LOWER WARMER | SOL | SW3 |
HALF BATCH OPTION | ||||
BLK | ||||
GRY | 1 | WHI | ||
SW4 | ||||
PNK | 2 | ORA | ||
BREW 3 | ||||
WHI/GRN | ||||
TAN | TIMER 4 | YEL | ||
5 |
120 VOLTS AC 2 WIRE |
10628.0001A 5/92 © 1991 BUNN-O-MATIC CORPORATION |
SINGLE PHASE |
SCHEMATIC WIRING DIAGRAM A10 A AUTO
L1 | SW. & | GRN/YEL | L2 | |
LIMIT | LIMIT | |||
SW1 | THERMOSTAT | |||
THERMOSTAT | THERMOSTAT | |||
BLK | BLU | BLK | 1000W | RED |
WHI | 40W | TANK HEATER | WHI | |
SW2 | 'KEEP WARM' HEATER | RED | ||
RED | 80W | RED | ||
BLK | BLK | LOWER WARMER | SOL | SW3 |
HALF BATCH OPTION | ||||
BLK | ||||
GRY | 1 | RED | ||
SW4 | ||||
PNK | 2 | ORA | ||
BREW | 3 | |||
WHI/GRN | ||||
TAN | TIMER 4 | YEL | ||
5 |
230 VOLTS AC 2 WIRE | 10627.0001A 5/92 © 1992 BUNN-O-MATIC CORPORATION |
SINGLE PHASE |